HEPA filter H14 EN1822

£14,000.00

HEPA Filter H14 EN1822 is a high-efficiency air filtration solution engineered to deliver exceptional particle retention for cleanrooms, pharmaceutical production, healthcare facilities, and critical industrial environments. Designed in compliance with EN1822 standards, it provides reliable removal of ultrafine contaminants while ensuring consistent airflow performance. Its robust construction and long service life help reduce maintenance costs and improve operational efficiency. Competitive Advantage: H14-grade filtration offers superior purification performance and dependable quality for demanding applications requiring stringent air cleanliness standards.

Category:

Description

  1. Product Overview

HEPA filter H14 EN1822 is a high-efficiency particulate air (HEPA) filter manufactured to meet the EN1822 H14 classification for separation efficiency. It is engineered for critical air-cleaning applications that demand ≥99.995% removal of 0.1–0.3 µm particles, providing reliable containment of airborne particulates, aerosols, and engineered dust. The filter’s primary industrial use is in contamination-sensitive environments—pharmaceutical production, semiconductor fabs, cleanrooms, medical device manufacturing, and high-precision laboratories—where particulate control is mission-critical to product quality and regulatory compliance. Strategically, H14 HEPA filters reduce risk of product rejection, protect worker health, and enable customers to meet stringent international clean-air standards, making them a core element of any enterprise-grade contamination control program.

  1. Key Specifications & Technical Characteristics

  • Filter classification: EN1822 H14 (efficiency ≥99.995% at MPPS).

  • Media material: Multi-layer borosilicate glass microfibers with electrostatic charge treatment (or equivalent high-performance synthetic glass fiber media).

  • Frame material: Rigid galvanized steel or extruded anodized aluminum; available with stainless-steel (304/316) frames for corrosive environments.

  • Seal & gasket: Continuous polyurethane or silicone gasket for airtight seal; optional neoprene for chemical-resistant applications.

  • Media pleat geometry: High-capacity mini-pleat (8–12 mm pitch) or standard pleat options for optimized airflow and dust holding.

  • Initial pressure drop: Typically 60–120 Pa at standard rated flow (subject to size); custom testing available.

  • Rated airflow per nominal size: Configurable; examples—595x595x292 mm, 1,020–1,700 m3/h nominal ranges depending on frame and pleat configuration.

  • Maximum operating temperature: Standard up to 70°C; high-temp variants up to 120°C.

  • Humidity tolerance: Up to 100% RH with appropriate gasket and frame selection; avoid sustained condensation on media.

  • Physical form & color: Rectangular rigid panel/cassette; media color off-white/cream, frame color metallic or painted per customer spec.

  • Particle size capture: Designed for maximum capture at MPPS (most penetrating particle size) typically 0.1–0.3 µm.

  • Leakage & integrity: Individually tested per EN1822 (MPPS scan or DOP/PAO scanning) with certificate of conformity; optional on-site integrity testing.

  • Shelf life: Recommended storage 24 months in dry, temperature-controlled conditions (5–25°C, <65% RH).

  • Packaging options: Cardboard palletized crates, shrink-wrapped on pallets, wooden crates for export; inner protective covers to prevent media contamination.

  • Customization: Dimensions, face velocity, frame material, gasket type, and performance validation can be tailored to customer specifications.

  1. Core Industrial Applications

  • Pharmaceutical and biotech manufacturing: Final-stage air filtration in cleanrooms (ISO 5–8), isolators, filling suites; ensures product sterility, reduces contamination-related batch losses, and supports regulatory audits (GMP compliance).

  • Semiconductor and electronics fabrication: Process tool and cleanroom filtration to protect wafers from sub-micron particles that cause defects; supports high yield and reduces rework.

  • Medical device and hospital HVAC systems: Critical-area filtration for operating rooms, laminar flow hoods, and HEPA-filtered enclosures; protects patients and sensitive products.

  • Aerospace and defense: Environmental control systems in assembly and testing facilities where particulate control impacts component integrity and safety.

  • Laboratories and research facilities: Biosafety cabinets, containment labs, and clean benches requiring certified filtration performance.
    Why it performs better: H14 EN1822 filters are designed and tested against a rigorous, particle-size-specific standard (EN1822), delivering verified performance at the most penetrating particle sizes. Advanced media construction and pleat geometry maximize dust-holding capacity and maintain lower pressure drop versus lower-class filters, extending service intervals and reducing fan energy consumption—yielding lower total cost of ownership compared with lower-efficiency or uncertified alternatives.

  1. Competitive Advantages

  • Quality consistency: Manufactured under controlled production protocols with batch-level EN1822 certification and traceable documentation; individual filter test reports supplied.

  • Supply reliability: Industrial-scale production capacity with scheduled production slots for long-term contracts and safety-stock strategies to support continuous operations.

  • Logistics capability: Export-ready packaging, palletized bulk shipment, and experience with international freight (FCL/LCL) and hazardous-material handling where applicable.

  • Price competitiveness: Competitive commercial pricing for bulk procurements (B2B volume tiers), with cost advantages from optimized pleat designs and material sourcing.

  • Sustainability: Options for recyclable frame materials and reduced packaging waste; media optimized for extended life to lower replacement frequency and lifecycle emissions.

  • Technical support: Application engineering, specification matching, on-site installation guidance, and commissioning support; supply of integrity test protocols and documentation for regulatory audits.

  • After-sales service: Spare-part availability, replacement schedules, and validation support to integrate into maintenance programs (e.g., FM, EHS, and QA teams).

  1. Commercial & Supply Information

  • Minimum order quantity (MOQ): BULK 20MT.

  • Loading capacity (MT per container): Typical loadings—20-foot container up to 20 MT (depending on packaging density and palletization); 40-foot container up to 24–26 MT with optimized packing.

  • Lead times: Standard production lead time varies by order size and customization; typical bulk lead 4–8 weeks from PO and deposit, expedited options available.

  • Incoterms & shipping: FOB, CIF, or DDP options available; documentation includes commercial invoice, packing list, certificate of conformity, and EN1822 test reports.

  • Payment terms: Negotiable—commonly 30% deposit, 70% prior to shipment; open account or LC terms for approved buyers.

  • Warranty: Conformance to specified EN1822 performance at delivery; warranty terms available for manufacturing defects.

Additional information

Price

per MT

Reviews

There are no reviews yet.

Be the first to review “HEPA filter H14 EN1822”

Your email address will not be published. Required fields are marked *

Add to cart